Validation Parameters of the Magnetic Stirrer Method for Pooled Sample Digestion for Trichinella spp. in Horse Meat Based on Proficiency Tests Results.

Opis bibliograficzny

Validation Parameters of the Magnetic Stirrer Method for Pooled Sample Digestion for Trichinella spp. in Horse Meat Based on Proficiency Tests Results. [AUT.] RÓŻYCKI MIROSŁAW, KORPYSA-DZIRBA WERONIKA, BEŁCIK ANETA, BILSKA-ZAJĄC EWA, KOCHANOWSKI MACIEJ, SAMOREK-PIERÓG MAŁGORZATA, KARAMON JACEK, RUBIOLA SELENE, CHIESA FRANCESCO, CENCEK TOMASZ, GONTARCZYK ANETA. International Journal of Environmental Research and Public Health. DOI: 10.3390/ijerph192114356
Skopiowane!
Kliknij opis aby skopiować do schowka

Szczegóły publikacji

Rok:2022
Język:angielski
Charakter formalny:Artykuł w czasopismie
Typ MNiSW/MEiN:inne

Streszczenia

Meat of horses may be infested with nematodes of the genus Trichinella spp. and can cause serious disease in humans. Rules for the carcasses sampling of species susceptible to Trichinella spp. infection and examination are laid down in Commission Regulation 1375/2015, where the magnetic stirrer method for pooled-sample digestion is recommended (Commission Regulation 1478/2020). All personnel involved in the examination should be properly trained and participate in quality control programs. Proficiency tests (PTs) play a key role in the quality verification process. This paper presents the results of PTs organized for 68 Polish laboratories in 2014–2019. Results were assessed qualitatively at three levels of sample contamination (0, 3, 5 larvae) and quantitatively at one level (5 larvae). The laboratories have achieved the average correct qualitative results 100%, 96.2% and 96.8% for the samples contaminated with 0, 3 and 5 larvae, respectively. In the quantitative evaluation, an average 94.1% of the reported results were correct. The data from PTs enabled us to define, for the first time, validation parameters of the digestion method for the horse meat matrix in a large-scale experiment including: specificity (100%), sensitivity (95.6%), accuracy (97.1%), the limit of detection (LOD) (1.14 ≈ 1) and the limit of quantification (LOQ) (3.42 ≈ 3).

Open Access

Tryb dostępu:otwarte czasopismoWersja tekstu:ostateczna wersja opublikowanaLicencja: Creative Commons - Uznanie Autorstwa (CC-BY) Czas udostępnienia:w momencie opublikowania

Identyfikatory

ISSN: 1661-7827
e-ISSN: 1660-4601
BPP ID: (7, 8861) wydawnictwo ciągłe #8861

Metryki

140,00
Punkty MNiSW/MEiN
0
Impact Factor
0
Index Copernicus
0
Punktacja wewnętrzna

Eksport cytowania

Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.

Skopiowane!

Informacje dodatkowe

Status:przed korektą
Praca recenzowana:nie
Rekord utworzony:2 kwietnia 2025 01:21
Ostatnia aktualizacja:4 czerwca 2025 13:40