Opis bibliograficzny

Inter-laboratory comparison of eleven quantitative or digital PCR assays for detection of proviral bovine leukemia virus in blood samples. [AUT.] PLUTA ANETA, JAWORSKI JUAN PABLO, DROSCHA CASEY, VANDERWEELE SOPHIE, TAXIS TASIA M., VALAS STEPHEN, BRNIĆ DRAGAN, JUNGIĆ ANDREJA, RUANO MARÍA JOSÉ, SÁNCHEZ AZUCENA, MURAKAMI KENJI, NAKAMURA KURUMI, PUENTES RODRIGO, DE BRUN MLAUREANA, RUIZ VANESA, GÓMEZ MARLA ELIANA LADERA, LENDEZ PAMELA, DOLCINI GUILLERMINA, CAMARGOS MARCELO FERNANDES, FONSECA ANTÔNIO, BARUA SUBARNA, WANG CHENGMING, GIZA ALEKSANDRA, KUŹMAK JACEK. BMC Veterinary Research. DOI: 10.1186/s12917-024-04228-z
Skopiowane!
Kliknij opis aby skopiować do schowka

Szczegóły publikacji

Rok:2024
Język:angielski
Charakter formalny:Artykuł w czasopismie
Typ MNiSW/MEiN:inne

Streszczenia

Bovine leukemia virus (BLV) is the etiological agent of enzootic bovine leukosis and causes a persistent infection that can leave cattle with no symptoms. Many countries have been able to successfully eradicate BLV through improved detection and management methods. However, with the increasing novel molecular detection methods there have been few efforts to standardize these results at global scale. This study aimed to determine the interlaboratory accuracy and agreement of 11 molecular tests in detecting BLV. Each qPCR/ddPCR method varied by target gene, primer design, DNA input and chemistries. DNA samples were extracted from blood of BLV-seropositive cattle and lyophilized to grant a better preservation during shipping to all participants around the globe. Twenty nine out of 44 samples were correctly identified by the 11 labs and all methods exhibited a diagnostic sensitivity between 74 and 100%. Agreement amongst different assays was linked to BLV copy numbers present in samples and the characteristics of each assay (i.e., BLV target sequence). Finally, the mean correlation value for all assays was within the range of strong correlation. This study highlights the importance of continuous need for standardization and harmonization amongst assays and the different participants. The results underscore the need of an international calibrator to estimate the efficiency (standard curve) of the different assays and improve quantitation accuracy. Additionally, this will inform future participants about the variability associated with emerging chemistries, methods, and technologies used to study BLV. Altogether, by improving tests performance worldwide it will positively aid in the eradication efforts.

Open Access

Tryb dostępu:otwarte czasopismoWersja tekstu:ostateczna wersja opublikowanaLicencja: Creative Commons - Uznanie Autorstwa (CC-BY) Czas udostępnienia:w momencie opublikowania

Identyfikatory

ISSN: 1746-6148
BPP ID: (7, 8495) wydawnictwo ciągłe #8495

Metryki

140,00
Punkty MNiSW/MEiN
0
Impact Factor
0
Index Copernicus
0
Punktacja wewnętrzna

Eksport cytowania

Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.

Skopiowane!

Informacje dodatkowe

Status:przed korektą
Praca recenzowana:nie
Rekord utworzony:2 kwietnia 2025 01:21
Ostatnia aktualizacja:6 listopada 2025 09:11