Development, in-house validation and application of a method using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) for the quantification of 12 ergot alkaloids in compound feeds.

Opis bibliograficzny

Development, in-house validation and application of a method using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) for the quantification of 12 ergot alkaloids in compound feeds. [AUT.] KOWALCZYK EWELINA, KWIATEK KRZYSZTOF. Journal of Veterinary Research (Poland). DOI: 10.2478/jvetres-2023-0070
Skopiowane!
Kliknij opis aby skopiować do schowka

Szczegóły publikacji

Rok:2023
Język:angielski
Charakter formalny:Artykuł w czasopismie
Typ MNiSW/MEiN:inne

Streszczenia

Introduction: Ergot alkaloids (EAs) are toxic substances naturally produced by Claviceps fungi. These fungi infest a widerange of cereals and grasses. When domestic animals are exposed to EAs through contaminated feeds, it is detrimental to them andleads to significant economic losses. For that reason, it is important to monitor feed for the presence of EAs, especially with methodsenabling their determination in processed materials. Material and Methods: Ergot alkaloids were extracted with acetonitrile, anddispersive solid phase extraction (d-SPE) was used for clean-up of the extracts. After evaporation, the extracts were reconstitutedin ammonium carbonate and acetonitrile and subjected to instrumental analysis using high-performance liquid chromatographywith fluorescence detection. The developed method was validated in terms of linearity, selectivity, repeatability, reproducibility,robustness, matrix effect, limits of quantification and detection and uncertainty. The EA content of 40 compound feeds wasdetermined. Results: All the assessed validation parameters fulfilled the requirements of Regulation (EU) 2021/808. At least oneof the monitored alkaloids was determined in 40% of the samples. The EAs with the highest incidence rate were ergocryptine,ergometrinine and ergocornine. The total concentrations of EAs ranged from under the limit of quantification to 62.3 μg kg−1.Conclusion: The results demonstrated that the developed method was suitable for simultaneously determining twelve EAs incompound feed and could be used for routine analysis

Open Access

Tryb dostępu:otwarte czasopismoWersja tekstu:ostateczna wersja opublikowanaLicencja: Creative Commons - Uznanie Autorstwa - Użycie niekomercyjne - Bez utworów zależnych (CC-BY-NC-ND) Czas udostępnienia:w momencie opublikowania

Identyfikatory

ISSN: 2450-7393
e-ISSN: 2450-8608
BPP ID: (7, 8458) wydawnictwo ciągłe #8458

Metryki

200,00
Punkty MNiSW/MEiN
0
Impact Factor
0
Index Copernicus
0
Punktacja wewnętrzna

Eksport cytowania

Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.

Skopiowane!

Informacje dodatkowe

Status:przed korektą
Praca recenzowana:nie
Rekord utworzony:2 kwietnia 2025 01:20
Ostatnia aktualizacja:4 czerwca 2025 13:40